Tremendous bleeding complication after vacuum-assisted sternal closure
Published: 9 February 2011
Abstract (provisional)
Vacuum-assisted closure (VAC) of complex infected wounds has recently gained popularity among various surgical specialties. The system is based on the application of negative pressure by controlled suction to the wound surface. The effectiveness of the VAC System on microcirculation and the promotion of granulation tissue proliferation are proved. In our case report we illustrate a scenario were a patient developed severe bleeding from the ascending aorta by penetration of wire fragments in the vessel. We conclude that all free particles in the sternum have to be removed completely before negative pressure is used.